Publicação: An alternative explanation of the origin of the signal in diffusion-weighted MRI
A carregar...
Ficheiros
Data
Autores
Título da revista
ISSN da revista
Título do Volume
Editora
Springer
Resumo
I formulated an alternative explanation for the origin of the signal in diffusion-weighted MRI (DWI) and tested it in a simple experimental model using gelatin. My findings indicate that the signal in DWI is influenced by the passage of water from the sol to the gel state, independently of the presence of cell structures or membrane-dependent diffusion.
Descrição
Citação
Neuroradiology. 2000;42(2):96-8.